Skip to product information

DuroMax

DuroMax XP15000HX 15,000-Watt/12,000-Watt Electric Start Dual Fuel Portable Generator

DuroMax XP15000HX 15,000-Watt/12,000-Watt Electric Start Dual Fuel Portable Generator

SKU: XP15000HX

Regular price
Price: $2,499.00
Regular price
List Price:
Sale price
Price: $2,499.00

General Overview:

The LARGEST single cylinder Dual Fuel 15,000 watt generator on the market has arrived! Introducing the brand new XP15000HX from DuroMax. With 15,000 watts of dual-fuel portable power, this unit will power your WHOLE home and all of your essentials during any power outage. The XP15000HX is the largest unit in the HX Series and comes equipped with a 50 amp plug, a 120V 30 amp plug, one 120/240V 30 amp plug, and TEN standard household outlets, giving you the ability to power everything you can imagine! Enjoy the freedom of fuel flexibility and run this unit on either gasoline or propane. The XP15000HX has smart "fuel select" technology that automatically recognizes when propane is connected and switches between fuel types automatically. Equipped with a push-button start and a state-of-the-art Digital Control Center, so you can monitor power output, load level, and running hours at a glance.

Features:
  • Power Your Entire Home

With 15,000 watts of power, the XP15000HX Dual Fuel generator will keep your whole home running during a storm or power outage, while protecting your family from harmful fumes with CO Alert.

  • Dual Fuel Technology

Enjoy the freedom and flexibility of running your generator on either gasoline or propane. Propane is cost-effective, clean-burning, fuel-efficient, low-maintenance, has a long shelf life, and is a readily available fuel source.

  • The Heart of a DuroMax

At the core of all our products resides a robust DuroMax engine. Designed for Power. Designed to Last.

  • Remote Start

During a storm, your safety is of the utmost importance. Start your generator from the comfort of your own home with the easy and convenient remote start.

Specifications:

 

Gasoline Propane
Peak Wattage 15,000 Peak Wattage 14,250
Running Wattage 12,000 Running Wattage 11,400
Running Amperage at 120V 100 Running Amperage at 120V 95
Running Amperage at 240V 50 Running Amperage at 240V 47.5
Runtime at 25% Load 18 Runtime at 25% Load 12.5
Runtime at 50% Load 12 Runtime at 50% Load 8.5
Panel Specifications
GFCI Outlets Yes
Battery Switch Yes
Volt Meter Digital
Hour Meter Yes
5-20R 10
L5-30R 1
L14-30R 1
14-50R 1
Engine & Emission Specifications Generator Specifications
Engine Manufacturer DuroMax Power Equipment Manufacturer DuroMax Power Equipment
Engine Type 4-Stroke Part # XP15000HX
Valve Type OHV Voltage 120/240 Volts
Engine Cooling Type Forced Air Total Harmonic Distortion (THD) Less than 5%
Engine Size 670cc GFCI Outlets Yes
Engine Speed 3600 RPM +/- 100 RPM 4 Foot Propane Hose & Regulator Included
Starting Type Push Button Winding Material 100% Copper Windings
Electric Start Yes Automatic Voltage Regulator Yes
Recoil Start Yes Battery Type 12V SLA
Remote Start Yes Battery Included Yes
Idle Control No Load Low Idle RV Ready Yes
Fuel Delivery System Carburetor Home Backup Ready Yes
Fuel Types Gasoline and Propane Fuel Tank Capacity Gasoline 13.2 Gallons
Oil Cooling Type Pressure and Splash Fuel Gauge Yes
Recommended Oil 10W-30 All Metal Construction Yes
Recommended Oil Types Blended, Conventional, or Synthetic Product Dimensions W/O packaging 36"-Long x 33.2"-Wide x 32"-High
Compatible Oil Filter STP S2878XL Product Weight W/O packaging 345-lbs
Oil Capacity 57.5 fluid oz Product Weight W/ Packaging 404-lbs
Suggested Propane Tank Size 60 lbs. minimum Volume @ 50% Load (db) 78 dB
Automatic Low Oil Shutdown Yes UPC 811640016845
Cast Iron Sleeve Yes Warranty 5 Year
Bearing Type 6003 Sliding Bearing Wheel & Handle Kit Included
CO Sensor Shutdown Yes Wheel Type Metal Hub
EPA Certified Yes Wheel Diameter 13-Inches
50 State Emissions No

 

What's in the Box:
  1. XP15000HX Generator
  2. Oil Funnel
  3. Spark Plug Wrench
  4. Tool Set
  5. Wheel & Handle Kit
  6. Propane Regulator
  7. Remote Control
  8. Owner's Manual
Product Documents:

Product Manual

Sales Sheet

Warranty:

5-Year Warranty

Warranty Document

FAQs

Generator Safety:


Where can I safely store the generator?
The generator should always be stored in a cool, dry area with the ventilation openings free from any obstructions. 

Where is it recommended to operate the generator?
The generator should be placed outdoors at least 5 ft in all directions from any flammable material, and at least 20 ft from any windows or doors. The generator should also be placed in a dry, weather-protected area. 

How do you safely transport a generator?
To safely transport the generator, the generator should be emptied of all gasoline prior to transport, and the generator's spark plug should be disconnected. Please note that you do not obstruct any ventilation openings, and keep the generator in a cool, dry area during transport.

Do alternative fuels to gasoline, like propane or natural gas, produce CO?
Yes, anytime any fuel is burned, even alternative fuels like propane or natural gas, the CO fumes will be produced, and the generator should always be running outdoors 20 ft from any windows or doors for safety.

Can the generator be operated directly in rain or snow?
No, the generator shouldn’t ever be operated directly in the rain or snow without some type of overhead protection to keep it protected from the elements. Please note that there are multiple generator weather protection options, including running generator tents that can be used to keep the generator dry during a rain or snowstorm.

 

Setup/Startup:


How to remove the generator shipping braces?
Step 1- Lay a large piece of foam from the generator packaging on a level surface.
Step 2- Flip the generator upside down onto the foam piece.
Step 3- Remove the brightly colored shipping braces located on the bottom of the generator.

Please note that the shipping braces should always be removed before any operation of the generator to avoid engine damage.
Please also note that the generator should never be filled with any oil or gasoline prior to removing shipping braces

How do you connect the generator battery?
When the generator is first received, the battery will have a disconnected negative lead to avoid the battery losing charge while in storage. The disconnected negative lead will be located above and behind the battery location. Take the disconnected end of the negative lead and bolt it to the negative battery post. Please note to be careful not to allow your tool or any other conductive object to touch the battery post and generator frame at the same time. 

What type of oil should I use in my generator?
If this is your first time using the generator, you should use a conventional 30W, 10W-30, or 5W-30 oil to help break the product in for the first 6-8 hours. After the product has been broken in, you can use either a synthetic or conventional oil, depending on preference, in either 30W, 10W-30, or 5W-30, depending on your climate. 10W30 will be sufficient for most temperatures; however, if ambient temperatures exceed 95°F, you should use 10W40.

How do you start the generator using the recoil start?
The first step to starting the generator using the recoil start will be to turn the circuit breaker and idle control feature to the “OFF” position. The second step will depend on the fuel used, if using gasoline turn the gasoline valve “ON”, and the fuel selector switch to the gasoline selection (if applicable for the generator model); if your using propane turn the gasoline valve “OFF” and move the fuel selector switch toward the propane selection (if applicable for the generator model), then connect your propane tank and turn the propane tank to the “ON” position; after the proper instructions are followed with starting on the desired fuel, move the battery switch to the “ON” position or if applicable move the start switch to the “RUN” or “ON” position depending on the generator model version. Finally, pull the recoil out slowly until tension is felt, then yank the recoil cord to start the generator; repeat this final step as necessary until the engine starts.

What type of gasoline should be used in the generator?
The generator will be compatible with 87 Octane gasoline or better with a 10% or less ethanol cut. Please note that the lower the ethanol content, the longer this can extend the life of your generator and parts.

 

Maintenance:


How to change the generator oil?
The first step will be to place the generator on a level surface before starting the oil change, then you’ll want to locate the generator drain bolt, which will be located on the center of the bottom protruding crankcase lip, and place a container below the oil drain bolt location. The next step is to remove the drain bolt with a 12 mm hex wrench and allow the oil to fully drain. Finally, replace the oil drain bolt and remove the main oil fill cap, then add oil until you see the oil on the oil cap threading. Please note that as long as you fill the oil on a level surface, the generator is built to spill out the excess oil before it can be overfilled. 

How to empty gasoline from your gas tank?
To remove the gasoline from the generator the first step will be to turn the fuel valve to the “OFF” position, and you’ll want to place a container under the fuel filter cup located on the bottom of the fuel valve, then remove the fuel filter cup and turn the fuel valve to the “ON” position to allow the gasoline to drain from the gas tank. Once fully drained, replace the fuel filter cup, and the draining process is complete. 

How to prepare your generator for storage?
To properly prepare the generator for storage, first turn the breaker “OFF” and run the generator for 3-5 minutes; then turn the fuel valve to the “OFF” position and allow the generator to run until it stalls out. The next step will be to turn the battery switch, or engine switch, depending on the model, to the “OFF” position, then remove the fuel filter cup, and drain the gas tank of all gasoline by turning the fuel valve to the “ON” position. The next step will be to remove the 2nd to the lowest bolt on the bottom of the carburetor bowl to remove any excess fuel from the carburetor bowl, and remove the spark plug; then add 2 tablespoons of 10W-30 oil into the spark plug hole and pull the recoil to help lubricate the cylinder. Finally, replace the spark plug, remove the battery, then charge the battery on a trickle charger. Please note that the generator should always be stored in a cool, dry location that’s protected from the elements and properly ventilated. 

How to properly maintain your generator battery?
The generator battery can lose charge in as little as 3 to 6 months of storage and should always be properly maintained. To properly maintain your generator battery, we’d recommend disconnecting the generator battery from your generator and hooking the battery up to any 12V trickle charger that’s compatible with SLA batteries. Please note that extremely cold or hot conditions can accelerate the rate at which the battery loses charge.

How frequently should I perform maintenance on my generator?
The maintenance can vary depending on the model and whether you’re running the generator with light or heavy use. To properly follow maintenance, please ensure that you read your full maintenance schedule in your included generator manual, and it’s recommended to keep track of your hours and maintenance performed in your manual maintenance log.


Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)